FAQ/ I want to operate the drainage station at the end of a tributary based on the water level of the main river.¶
We are trying to simulate inland floods for tributaries that are strongly affected by the backwaters of the main river. Downstream of this tributary, water flows back from the main river.
For this tributary, we installed a drainage station at the end of the stream.
For this drainage station, when the main river water level reaches the closed water level, we want to close the sluice gate and operate the pump.
Also, if the water level of the main river has not reached the closed water level, we would like to open the sluice gate and stop the pump. Is this configurable?
response¶
It's possible.
Set the properties of the drainage station [Mode of operation] [Pump + Himon] to and set [Operation rules] to [Outside water level + natural flow] .
For more information, please refer to Technical Reference / Boundary Conditions - End-of-Flow Drainage Station .